Home> Products > AVR / Voltage Stabilizer / Power Line Conditioner > INDUSTRIAL Grade AVR, INDOOR > INDUSTRIAL Grade AVR, Servo Motor Type (1 Phase 1 ~ 30KVA)
INDUSTRIAL Grade AVR, Servo Motor Type (1 Phase 1 ~ 30KVA)

Model:

SPS series

Type:
Servo Motor Type
Capacity: 1 phase
1~30KVA
Made in
Taiwan, ROC
CNC Machines, SMT Precise Measuring & Testing Equipment
Laser Cutting Machine Generator
Process Control System GSM Base Station
Military Research & Defense Weapons Medical Equipment
Auto-testing Equipment TV & Radio Broadcasting Stations
Medical Monitoring System    
Simple & Reliable AVR You can Trust!
 
+25 % / -30 %  WIDE INPUT VOLTAGE RANGE
 

±15 % as standard. ±20 %, ±25 %, ±30 %, ±40 % or others are available

  on request.
±1% ~ ±2% PRECISE & LINEAR VOLTAGE REGULATION RATE
 

Output Voltage Accuracy can be stabilized within a safety working range,

  even in high voltage fluctuation areas.
ADJUSTABLE OUTPUT VOLTAGE ACCURACY
 

±1 % ~ ±5 % Output voltage accuracy is adjustable

BETTER THAN 98 % VA EFFICIENCY, FROM 0 TO 100 % LOAD
 

Very low losses and minimal heat dissipation.

HIGHER LEVEL OF SURGE AND LIGHTNING PROTECTION
 

Special design to deal with high level protection for Telecommunication

  applications and for equipment that require a higher level of Surge,
  Spike & Noise Protection.
REVOLUTIONARY VARIAC / SLIDAC AND CARBON BRUSH
 

Improve its inherent weakness in order to prolong the service life of AVR.

  For further introduction, please refer to the Chapter of "MAIN STRUCTURE
  & KEY COMPONENTS"
INDEPENDENT PHASE CONTROL (3PHASE UNITS)
 

Independent voltage regulation. Every phase remains ±2 % output voltage

  when AC power encounters 30 % phase unbalanced, non-linear loads
  or heavy loads.
STRONG OVERLOAD CAPABILITY
 

Sustained 200 % of its rated loading capacity, no voltage goes down extremely.

SOFT START LOAD PROTECTION
 

Ensure the output voltage starts up from the lowest voltage when it commences

  full stabilization.
FULL PROTECTION
 

Input Circuit Breaker, Magnetic Contactor for abnormal protection of :

  Over Voltage Protection:
   

If Input voltage exceeds voltage regulation range, the AVR will cut off output

    voltage automatically and shield abnormal voltage enters into the AVR directly
    or burn circuit boards.
  Under Voltage Protection:
   

When Input voltage is too low, it will cause malfunctions of machinery

    automation; Product failure rate will increase as well.
  Phase Failure Protection:
   

Should one of the electric wires is disconnected abruptly while AVR is working,

   

the AVR will cut off at once and Red light indicator is flashing. Verify if the

   

connected equipment remains in Safety Electrical mode and prevent the load

    from serious damage.
  Time Delay-off & Soft Start Protection:
    Instantaneous power blackouts and recovery will damage electrical loads.
    While AC power recovery, the AVR starts automatically from low voltage
   

output, to ensure the security of load

MANUAL MAINTENANCE BYPASS SWITCH
 

The switch is for periodically maintenance and service. Not affect machinery

running in any ways.

CONCEALED NON-FUSE CIRCUIT BREAKER
  Prevent man-made damage or careless machine shutdown. Fitted with
 

Overload protection.

SAFETY HIDING-STYLE SWITCH SHIELD
 

Prevent damage or man-made wrong action during transportation which

  would cause no voltage output.
COMPLIANCE WITH INTERNATIONAL STANDARDS
  Electro-Magnetic Compatibility (EMC) Directive: IEC61000-4-2 / 3 / 4 / 5 / 6 / 8 / 11,
  Low Voltage Directive (Safety): EN61000-6-2 / 4
CE CONFORMITY
  European Union Directives 2004/108/EC (The EMC Directive) and
  2006/95/EC (The Low Voltage Directive)
CUSTOMIZATION WELCOME
  Please contact us, we will welcome the opportunity to review your problems and
 

provide you with necessary solutions.

TECHNICAL SPECIFICATION (SINGLE PHASE) : 

 Model

SPS-1102

SPS-1103 SPS-1105 SPS-1107 SPS-1110 SPS-1115 SPS-1120 SPS-1125 SPS-1130
Capacity (KVA)  2 3  5  7.5  10 15  20  25  30
   INPUT         
 Phase & Wire    1Phase 2Wire+G or 1Phase 3Wire+G
 Input Voltage A: 110V System: 1Phase 2Wire+G, 100/110/115/120V;
B: 220V System: 1Phase 2Wire+G, 200/220/230/240V;
C: c/w Isolation Transformer or 1Phase 3Wire+G
 or other specific voltage (as client demand)
 Input Voltage Range  ±15% (option: ±20%, ±25%, ±30% or others)
Frequency   50Hz/60Hz ±5%
Power Factor   0.95~1
  OUTPUT

Output Voltage

A: 110V System: 1Phase 2Wire+G, 100/110/115/120V;
B: 220V System: 1Phase 2Wire+G, 200/220/230/240V;
C: c/w Isolation Transformer or 1Phase 3Wire+G
or other specific voltage (as client demand)
Voltage Regulation Rate ±1% ~ ±2%
Output Voltage Adjustable    ±1% ~ ±5%
Frequency 50Hz/60Hz ±5%
Efficiency   >/= 98% (AC to AC)
Distortion Less than 1% adds
Response Time   0.1 seconds / 20V
Overload Capacity 150% for 10 seconds; 200% for 2 seconds
Auto Restart   Auto Restart while AC is recovery
  PROTECTION
Over Voltage  Option
Under Voltage Option
Manual Bypass  Switch to Mains Supply for Service / Maintenance
Over Load   Auto Cut off when overload
Lighting Standard Feature
  INDICATORS
Output Voltmeter Analog Voltmeter or Digital Display
Power On/Off Standard Feature
Working Environment 0℃~45℃ / 0%~95% (non-condensing)
A & B Type (W*H*D / cm)  20*20*36  26.6*21.5*44 30*48*51 30*48*51 
C Type (W*H*D / cm) 30*48*51 47*87*50 55*98*55
Weight- A & B (Kgs)  17 18  27 34 48 55 68 76 83
Weight- C (Kgs) 52 59 75 120 143 155 173 216 260

 • All specifications are subject to change without prior notice.

AUTO RESTORE WHILE AC RECOVERY
 

The system to be automatically switched into operation when power is restored (automatically) during a power failure.

H-GRADE ISOLATION TRANSFORMER (DELTA/WYE)
 

Galvanic isolated is used to protect against electric shock, to suppress electrical noise in sensitive devices.

SPD (Surge Protective Device) or
  TVSS (Transient Voltage Suppressors) Protection

Lightning Protector

Outdoor Enclosure
MAIN STRUCTURE & KEY COMPONENTS
 

1.

 

Aluminum Central Axle of Main Frame:

Prevent loosen and have better heat dissipation.

2. Easy and Simple to Replace Carbon Brush:


Unlike traditional type of carbon brush, it takes only

5 mins and one screwdriver to replace.

3. Special Resin Treatment:


Smooth contact surface to reduce spark occurred rate.

4. Nut type terminals:


The nuts are rigid, not easily broken and can fasten tightly.

5. Molded Variac / Slidac  


•  Molded Round Carbon Brush Plate :

   Carbon brush sustains physcial strength evenly in

   every angle

•  Even-spreaded Windings

•  H-Grade Enamel-insulated Wire:180°C Heat

   Resistance. 

•  Endurable Quality

6. Japan-made Carbon Alloy Brush


Endurable Quality. After 200,000 cycles continuous

friction tested in I.T.R.I., a government owned institute,

no wornout on the surface of carbon alloy brush.

7.

LED Display R-S-T Phase Working Status & Voltage