Home> Products > Uninterruptible Power System (UPS) > Commercial UPS > On Line UPS (Transformerless) > 1 Phase On-line UPS, Tower Type - 6KVA~10KVA
1 Phase On-line UPS, Tower Type - 6KVA~10KVA

Model:

SUI-1106 to 10

Type:

Tower

Capacity:

Single Phase 6~10KVA

Made in

Taiwan, ROC


ATM / ADM Network & Data Center
Computers OA Facilities
Computer Center Security Monitoring PC or Server
Emergency Lightning Telecommunication Equipments
Hospitals / Medical Instrument Any Equipments which required
Lan File Server High Stability Power Protection

 High Performance

True Double Conversion On-line UPS !
High Performance True Double Conversion On-Line UPS
External Battery Bank (Option) to Extended Back-up Time
N+X Parallel Redundancy and Capacity Expansion (Option)
Microprocessor Control Guarantees High Reliability
Individual Power Distribution Unit (PDU) 
  c/w Maintenance Bypass Switch (Option)
Low Heat Dissipation in Long Time Operation
input THDi < 5%; Output THD < 2%
Emergency Power Off Function (EPO)
High Efficiency Mode (ECO Mode)
Fan Speed Control & DC Start
 • Output Voltage Regulation <1%
Isolation Transformer (Option)
Automatic Self-testing Function
Power Management Software
Output Power Factor 0.9
Model SUI-1106 SUI-1106L SUI-1110 SUI-1110L
Capacity 6KVA / 5.4KW 6KVA / 5.4KW 10KVA / 9KW 10KVA / 9KW
   INPUT
Phase 1Phase 2Wire+G
Voltage 208 / 220 / 230 / 240Vac     
Frequency 50Hz or 60Hz (Auto Sensing)     
THDi < 5% with Resistor Full Load
   OUTPUT
Phase

1 Phase 2 Wire+G or 1 Phase 3 Wires+G (With Isolation Transformer)

Voltage

1 Phase 2 Wire+G: 208 / 220 / 230 / 240Vac;

1 Phase 3 Wires+G: 110/220 or 115 / 230 or 120 / 240Vac

Voltage Regulation +/-1% (+/-2% with Isolation Transformer)
Waveform Pure Sinewave
THD <2% (Linear Load) or <5% (Non-linear Load)
Crest Factor 3 : 1
Maintenance Bypass Standard Feature
    EFFICIENCY  
To AC Mode >92% at Full Load and Battery Full Charged     
To Battery Mode       >92% at Full Load and 12Vdc / Battery   
ECO Mode >96% at Full Load and Battery Full Charged
    BATTERY  
Voltage 240Vdc     
Type 12V/7AH*20 Extendable 12V/9AH*20 Extendable
Recharge Time  7Hrs to 90% Depend on Capacity of External Battery 8Hrs to 90% Depend on Capacity of External Battery
   TRANSFER TIME
Line to Battery 0ms
Inverter to Bypass 0ms
ECO Mode to Inverter < 10ms
   DISPLAY
LED Normal (Green), Bypass (Yellow), Fault (Red), Battery (Yellow)
LCD Load Level / Battery Voltage / Battery Mode / AC Mode / Bypass Mode Information
   AUDIBLE ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
UPS Fault Continuously sounding
   COMMUNICATIONS
Interface (Port) Dry Contact (Option), USB
Intelligent Slot Slot for SNMP or AS-400 (Option)
EPO Emergency Power Off
   ENVIRONMENT
Temperature 0~40°C (32°F~104°F)
Humidity 0~95% (Non-condensing)
Acoustic Noise <50dB at 1Meter distance
   PHYSICAL
Dimension (W*H*D) 260*710*685mm
External Battery Bank
  To Extend Back-up Time
   
Built-in Isolation Transformer
  With built-in Isolation Transformer, the UPS will offer full isolation and complete
  common mode noise rejection (N-G = 0) for connected precious equipment.
  It becomes an ideal power source with 100% protection against unexpected
  AC Power problems.
 
Power Distribution Unit for SUI Series Tower Type On-line UPS
A "Power Distribution Unit (PDU) is a device fitted with multiple outputs designed to 
distribute electric power, especially to racks of computers and networking equipment  
located within a data center.
SUI series 1KVA to 20KVA True Double Conversion On Line UPS is made with
individual "Power Distribution Unit (PDU)".
 
With PDU, UPS provides continuous power to connected equipment during
maintenance via a simple rotary switch.
 
With PDU, users or engineers do not need to unplug all connected devices anymore
when UPS is going with regular maintenance.  When UPS comes back from regular
maintenance, engineers can simply assemble PDU with UPS and do not need to
make wire connection to utility power again.  It efficiently saves cost and labor hours
on UPS maintenance.
 
With PDU, On Line UPS system becomes HOT SWAPPABLE.