Home> Products > Uninterruptible Power System (UPS) > Commercial UPS > On Line UPS (Transformerless) > 1 Phase On-line UPS, Tower Type - 1KVA~3KVA
1 Phase On-line UPS, Tower Type - 1KVA~3KVA

Model:

SUI-1101 to 3

Type:

TOWER

Capacity:

Single Phase 1~3KVA

Made in

Taiwan, ROC

ATM / ADM Medical Instrument / Hospitals
Computers Security Monitoring PC or Server
Computer Center Telecommunication Equipments
Lan File Server Any Equipments which required
Network & Data Center •  High Stability Power Protection
Emergency Lightning    

 

Tower Cabinet

Comprehensive LCD Display!

   
 •  High Performance True Double Conversion On Line UPS 1 ~ 3KVA
Intelligent Slot (SNMP) + USB Multiple Communications
Individual Power Distribution Unit (PDU)
  c/w Maintenance Bypass Switch (Optional for 3KVA)
Microprocessor Control Guarantees High Reliability
External Battery Bank (Option) to Extend Back-up Time
High Efficiency Mode (ECO Mode) Save Electricity
Low Heat Dissipation in Long Time Operation
Emergency Power Off (EPO) Function
Automatic Self-testing Function
Wide Input Voltage Range
< 2% Output Voltage Regulation
Power Management Software
0.8 Output Power Factor
Fan Speed Control
DC Start Function

 Model      SUI-1101    SUI-1101L SUI-1103 SUI-1103L
 Capacity 1KVA / 0.8KW 1KVA / 0.8KW 3KVA / 2.4KW 3KVA / 2.4KW
 Type Standard Backup Long Backup Standard Backup Long Backup
   INPUT
 Phase 1 Phase 2 Wire+Ground
 Voltage 110V  System 100 / 110 / 115 / 120Vac: 55~150Vac          
 Voltage 220V System 200 / 208 / 220 / 230 / 240Vac: 110~300Vac
 Frequeny 50Hz or 60Hz (Auto Sensing)
 THDi <5% at Full Load
    OUTPUT

 Voltage

 Regulation

110V System 100 / 110 / 115 / 120Vac: <1%
220V System 200 / 220 / 230 / 240Vac: +/-2%

 Frequency 

 (Battery

 Mode)  

110V System 100 / 110 / 115 / 120Vac: 50Hz or 60Hz +/-0.1Hz
220V System   200 / 220 / 230 / 240Vac: 50Hz or 60Hz +/-0.2Hz
 Waveform Pure Sinewave
 THD 110V System

<4%(Linear Load) ; <8% (Non-linear Load)

 THD 220V System

<3% (Linear Load); <5% (Non-linear Load)

 Crest Factor 3 : 1
    EFFICIENCY
 To AC Mode

110V System:>89% at Full Load & Battry Full Charged; 220V System:>88%

 To Battery Mode 110V System:>85% at Full Load & Battery Full Charged; 220V System:>85%
 To ECO Mode 110V System:>95% at Full Load & Battery Full Charged; 220V System:>93%
    BATTERY
 Voltage 36Vdc

110V System: 72Vdc;

220V System: 96Vdc

 Type 12V/7AH*3pcs Extendable

72Vdc:12V/9AH*6;

96Vdc:12V/7AH*8

Extendable
 Recharge Time 5Hrs to 90% Depend on Capacity of External Battery 5Hrs to 90% Depend on Capacity of External Battery
    TRANSFER TIME

 Line Mode to 

 Battery Mode

0ms   

 Inverter to Bypass, 

 ECO Mode

<4ms

 ECO Mode to

 Inverter

<10ms
    DISPLAY
 LCD Input, Output, Load, Battery, Mode / Fault / Warning Code, Inverter Operating, Bypass Operating, Output Voltage & Frequency & Bypass Disable / Enable Selection Information
    AUDIBLE ALARM
 Battery Mode Sounding Every 4 Seconds

 Battery Low

Sounding Every Second
 UPS Fault Continuously Sounding
 Overload Sounding Twice Every Second
    COMMUNICATIONS
 Interface (Port) USB Port
 Intelligent Slot Slot for SNMP or AS400 Card (Option)
 EPO (Option) Emergency Power Off
    ENVIRONMENT
 Temperature 110V System: 0~40°C; 220V System: 0~45°C
 Humidity 20~90%, non-condensing
 Acoustic Noise 110V System: <45dB at 1M; 220V System: <50dB at 1M 
    PHYSICAL

 Dimension (D*W*H)

420*145*230mm 420*145*230mm 560*193*346mm 560*193*346mm

* The specs are subject to change without prior notice.

Plug and Socket
  Plug Item Plug Item Socket Item Socket Item
      P01    P11     S01    S11
  P02 P12   S02   S12
  P03 P13   S03   S13
  P04   P14   S04   S14
  P05   P15   S05   S15
  P06   P16   S06   S16
  P07   P17   S07   S17
  P08   P18   S08   S18
  P09   P19   S09   S19
  P10       S10   S20
   
External Battery Bank
  To Extend Back-up Time
   
Built-in Isolation Transformer
  With built-in isolation transformer, the UPS will offer full isolation and complete
  common mode noise rejection (N-G = 0) for connected precious equipment.
  It becomes an ideal power source with 100% protection against unexpected
  AC Power problems.
 
Power Distribution Unit (PDU) for SUI-Tower Type :
The module of Power Distribution Unit (PDU) is assembled on UPS rear panel.
When UPS is sent for maintenance, it is not necessary to unplug all connected
devices. Please set UPS on Bypass mode and then remove the metal cover on 
Maintenance Bypass Switch. After metal cover is removed, a rotary switch is
seen. Switch the rotary switch from "INV" to "MAINT" and afterwords screw out
all screws on PDU. After all screws are removed, it is okay to dismantle PDU from
UPS rear panel. After PDU is dismantled from UPS rear panel.  UPS can be sent
for maintenance individually, PDU works as power strip and continues to supply
power to connected device.
 
Introduction :
SUI series 1 Phase Commercial Grade On-line UPS make use of the unique AC-DC
conversion circuitry to detect the electricity current and voltage output of utility supply.
The current is input via the high frequency PWM to maintain uniform wave form and
phase in line with the voltage, so as to attain high input power factor over 95% and
avoid generating comparatively significant harmonic interference on the power
network. With the use of the outstanding IGBT as the power conversation component,
the operating frequency of the Inverter of UPS is capable of reaching tens of KHz,
due to the high frequency operating characteristics of IGBT.  Higher working efficiency
of the Inverter also improves the overall efficiency of UPS.  Moreover, higher inversion
frequency reduces the noise of the Inverter as well.
 
Block Diagram :